- Clamp Meters
- Current Probes
- Anemometers
- Digital Multimeters
- Flexible Clamp Meters
- Ground Resistance Testers
- Temperature Calibrator
- Calibrators
- Leakage Current Testers
- Micro Ohmmeters
- Power Quality Analyzers (3-Phase)
- Power Quality Clamps (3-Phase)
- Power Quality Clamps (1-Phase)
- Programmable Power Supplies
- PV Analyzers
- Tachometers
- Thermometer/Dataloggers
- Transformer Turns Ratio Meter
Micro Ohmmeters
PROVA 700Milli-Ohmmeter
PROVA 700Milli-Ohmmeter
■ Best resolution 1μΩ. Accuracy 0.05%.
■ 5A (120 mΩ) max. test current.
■ Manual or Auto range. (There are 6 ranges of current measurement, and furthermore 3 ranges in each current range.)
■ Measurement of resistive and inductive materials (Two terminal measurement; Four terminal Kelvin measurement).
■ Programmable Hi-Lo alarm with memory of 20 data.
■ Auto-judgments of Hi (readings higher than Hi-Limit), Lo (readings lower than Lo-Limit) and Pass (readings between Hi-Lo Limits). Alarm (beeper) for Hi and Lo.
■ Readings Hold function.
■ Cable length measurement. The length unit can be selected between Meter (M) and Feet (FT).
■ Resistance measurement results excluding cable resistances.
■ Memory of 3,000 measurement data.
■ Large LCD (5-digit) with backlight (users can choose to disable it).
■ Rechargeable lithium battery and AC adaptor.
■ Low battery (voltage) alarm.
■ Low power consumption.
■ Communicate with PC via RS232C (to USB bridge) cable.
■ Application: various low-resistance (cables) measurement; contact resistance measurement, …etc.
■ Best resolution 1μΩ. Accuracy 0.05%.
■ 5A (120 mΩ) max. test current.
■ Manual or Auto range. (There are 6 ranges of current measurement, and furthermore 3 ranges in each current range.)
■ Measurement of resistive and inductive materials (Two terminal measurement; Four terminal Kelvin measurement).
■ Programmable Hi-Lo alarm with memory of 20 data.
■ Auto-judgments of Hi (readings higher than Hi-Limit), Lo (readings lower than Lo-Limit) and Pass (readings between Hi-Lo Limits). Alarm (beeper) for Hi and Lo.
■ Readings Hold function.
■ Cable length measurement. The length unit can be selected between Meter (M) and Feet (FT).
■ Resistance measurement results excluding cable resistances.
■ Memory of 3,000 measurement data.
■ Large LCD (5-digit) with backlight (users can choose to disable it).
■ Rechargeable lithium battery and AC adaptor.
■ Low battery (voltage) alarm.
■ Low power consumption.
■ Communicate with PC via RS232C (to USB bridge) cable.
■ Application: various low-resistance (cables) measurement; contact resistance measurement, …etc.